Time Ranges  0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min
max. selectable)
Rated supply voltage
*5 *6
24, 100 to 120, 200 to 230 VAC (50/60 Hz) *1
12, 24, 48, 100 to 110, 125 VDC *2
Pin type Plug-in
Operating mode On-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch)
Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) *3
Power consumption 100 to 120 VAC:
Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz
Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz
200 to 230 VAC:
Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz
Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz
24 VAC:
Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz
Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz
12 VDC:
Relay ON: Approx. 1.1 W at 12 VDC
Relay OFF: Approx. 0.1 W at 12 VDC
24 VDC:
Relay ON: Approx. 1.1 W at 24 VDC
Relay OFF: Approx. 0.1 W at 24 VDC
48 VDC:
Relay ON: Approx. 1.2 W at 48 VDC
Relay OFF: Approx. 0.3 W at 48 VDC
100 to 110 VDC:
Relay ON: Approx. 1.6 W at 110 VDC
Relay OFF: Approx. 0.4 W at 110 VDC
125 VDC:
Relay ON: Approx. 1.6 W at 125 VDC
Relay OFF: Approx. 0.4 W at 125 VDC
Control outputs DPDT:
5 A at 250 VAC, resistive load (cosf = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag
4PDT:
3 A at 250 VAC, resistive load (cosf = 1)
H3YN-4/-41 series: The minimum applicable load is 1 mA at 1 VDC (P reference value).
H3YN-4-Z/-41-Z series: The minimum applicable load is 1 mA at 1 VDC
(P reference value).
Contact materials: Au-clad + Ag-alloy
Ambient operating temperature -10°C to 50°C (with no icing)
Storage temperature -25°C to 65°C
Ambient operating humidity 35% to 85%